Description
This process is intended to be used for setting scalar values (bool
, int
, double
) to a variable in a model part.
This process is executed on the following hooks:
ExecuteInitialize
Parameters & Defaults
{
"model_part_name":"PLEASE_CHOOSE_MODEL_PART_NAME",
"mesh_id": 0,
"variable_name": "PLEASE_PRESCRIBE_VARIABLE_NAME",
"is_fixed": false,
"value" : 1.0
}
model_part_name
: Name of the modelpart in wich the scalar variable will be applied
mesh_id
: Id of the internal mesh to which the process will be applied. Default 0
.
variable_name
: Name of the variable in which the scalar value will be applied.
is_fixed
: Sets the value as fixed (true
) or not fixed (false
).
value
: Scalar value that will be applied.